VENTILATION SPECIALISTS · CORK

Good air.
By design.

Ventilation design, commissioning and validation. Built around your home.

Ventilation designs by a qualified Mechanical Engineer.

NSAI-registered Ventilation Validator

Cork, IrelandNew builds, Retrofits & existing homes
A bright contemporary home with a white ceiling supply valve. An animated overlay illustrates fresh air entering the room.
THE DETAIL THAT MAKES A DIFFERENCEComfort you can feel.
Airflow you can measure.
Designed for your homeBalanced for everyday comfortMeasured on site

01 / OUR SERVICES

The right design.
The right airflow.

From a considered design to measured airflow and a clear record of performance.

01

Ventilation design

All ventilation designs are completed by a qualified Mechanical Engineer. Plan the airflow before the installation. A considered layout brings the system, duct routes and room requirements together.

  • Residential ventilation and MVHR layouts
  • Room-by-room airflow planning
  • Duct routes and terminal positioning
  • Clear information for your installer
Talk to us about a design
02

Commissioning

Check what your installed system is actually delivering. Measure, adjust and balance the airflow, with a clear record of the results.

  • On-site airflow measurements
  • Supply and extract balancing
  • System settings review
  • Commissioning results and handover
Arrange a commissioning visit
03

Ventilation validation

Verify the installed system against the project requirements. Identify shortfalls and document the findings clearly.

  • Review of system and design information
  • Checks of delivered ventilation rates
  • Recorded findings and any remedial items
  • Validation scope agreed before booking
Discuss validation

02 / WHY VENTILATION MATTERS

A warmer home
still needs fresh air.

Insulation keeps heat in. Ventilation gives moisture and stale air a way out.

Everyday cooking, showers and drying clothes release moisture. A planned ventilation system helps remove it, while bringing outdoor air into the rooms you live in.

Manage moisture

Help control humidity and reduce condensation risk.

Refresh indoor air

Dilute indoor pollutants and remove everyday odours.

Protect comfort

Plan air movement, noise and heat loss together.

Check performance

Know what reaches each room through measured airflow.

Ventilation is only part of the picture. Persistent damp or mould can also involve leaks, cold surfaces or building defects that need investigation.

03 / KNOW YOUR OPTIONS

The right system.
For the right reasons.

Airtightness, layout, access and budget all matter. Here are the benefits and the trade-offs.

HEAT RECOVERY

MVHR

Mechanical ventilation with heat recovery

Supplies filtered outdoor air to living rooms and bedrooms, and extracts from wet rooms. A heat exchanger transfers heat from outgoing air to the incoming supply.

Why choose it

Controlled supply and extract, filtration and reduced ventilation heat loss.

What to weigh up

More ductwork, higher initial cost and space for an accessible unit. Filters need regular attention; performance depends on airtightness and commissioning.

Worth considering: airtight new builds and deep retrofits with space for supply and extract ducts.

CONTINUOUS EXTRACTION

MEV

Mechanical extract ventilation

Continuously removes air from kitchens, bathrooms and utility rooms. Replacement air enters through designed background air inlets.

Why choose it

No separate supply duct network. Centralised or decentralised arrangements can suit different layouts.

What to weigh up

No heat recovery from extracted air. Air inlets and room-to-room transfer paths are essential and need careful positioning for comfort.

Worth considering: homes where full MVHR duct routes are difficult or the upgrade scope is limited.

RESPONDS TO DEMAND

DCV

Demand-controlled ventilation

Uses controls or sensors to vary ventilation with demand, such as humidity or occupancy. DCV describes a control approach, rather than one fixed system layout.

Why choose it

Can adapt airflow as the needs of the home change, limiting unnecessary ventilation when demand is lower.

What to weigh up

Sensors, air inlets and controls must work as a complete system. Heat recovery is not implied by the DCV label.

Worth considering: projects where responsive airflow suits the proposed ventilation strategy.

A starting point for your project: SEAI’s guide to ventilation systems ↗

04 / NEW BUILD & RETROFIT

Plan the air.
Before closing the ceiling.

The easiest time to solve a duct route is while it is still a line on a drawing.

BUILDING NEW

Get it into the design early.

Coordinate the unit, ducts and ceiling terminals with the structure, insulation and other services. Allow access for filter changes and future maintenance.

  • Review floor plans and room uses.
  • Plan supply, extract and transfer paths.
  • Consider noise, duct resistance and external terminals.
  • Arrange commissioning before handover.
UPGRADING AN EXISTING HOME

Work with the home you have.

New windows and airtightness work change how a home breathes. Review ventilation alongside those upgrades, rather than waiting for condensation to appear.

  • Assess existing vents, fans and moisture concerns.
  • Use airtightness information to inform the choice.
  • Check attic space, access and duct routes.
  • Compare disruption, cost and ongoing maintenance.
A full retrofit is not the only starting point.If your existing system is noisy, poorly balanced or struggling with moisture, tell us what you are noticing. We can agree an appropriate review.Discuss your home ↗

05 / DETAILS THAT MATTER

Installed is one thing.
Working is another.

A fan running does not prove that each room is receiving the airflow it needs.

Commissioning sets it up.

Measure airflow at terminals, adjust the system and balance it against the design. Record the settings and explain operation at handover.

Validation checks the result.

Review and verify the installation against the agreed requirements. Confirm the required documentation and any independence requirements before the visit.

Small mistakes can have a big effect.

Crushed ducts, excessive bends, blocked inlets, missing transfer paths and inaccessible filters can undermine a good design. Restricting terminals to hide noise can leave rooms under-ventilated.

06 / HOW CARROLL TECHNICAL WORKS

Built around
your home.

Practical advice. Careful attention to detail. A straightforward conversation about what your project needs.

  1. 01

    Start with the project

    Tell us where you’re building, what stage you’re at and whether you need design, commissioning or validation.

  2. 02

    Agree the scope

    We’ll review your plans or system details, then agree the work, timing and fee with you.

  3. 03

    Get clear next steps

    Receive the design information, commissioning record or validation findings you need to move your project forward.

QUALIFICATIONS & TRAINING

Engineering knowledge.
Practical ventilation design.

All ventilation designs are completed by a qualified Mechanical Engineer, supported by training in Nearly Zero Energy Building (NZEB) principles and ventilation.

NSAI-registered Ventilation Validator. Independent validation of ventilation system performance against the design requirements.

NSAI Certified Ventilation Validator I.S. EN 14134:2019
WWETB NZEB Ventilation training badge, City and Guilds Assured
NZEB Ventilation
WWETB NZEB Fundamental Awareness Programme training badge, City and Guilds Assured
NZEB Fundamental Awareness

07 / YOUR QUESTIONS

Clear answers.
Better decisions.

Is MVHR right for every home?

No. It depends on airtightness, layout, duct routes, budget and the work planned. An assessment can establish whether heat recovery or an extract-based strategy is appropriate.

Will ventilation solve condensation and mould?

It can help when excess indoor moisture and inadequate air exchange are contributing. It will not repair a leaking roof or eliminate a cold bridge. Persistent problems need their causes investigated.

Can I still open the windows?

Yes. Mechanical ventilation does not prevent you opening windows. A whole-home system is intended to provide planned background ventilation without relying on repeated window opening.

Does MVHR heat or cool the house?

It recovers some heat that would otherwise leave with extracted air. It is not a replacement for your heating system or air conditioning. A summer bypass does not provide active cooling.

What maintenance is involved?

Follow the manufacturer’s schedule. Depending on the system, this includes inspecting or changing filters, keeping terminals and inlets clear, and checking the unit and controls. Do not change balanced terminal settings while cleaning.

When should I arrange commissioning?

When installation is complete and the home is ready for representative measurements. Share the drawings, system details and project programme beforehand so readiness and the required records can be agreed.

How much does the service cost?

The fee depends on the property, system, location and scope. Send your plans or system details for a project-specific quotation before booking.

Do you provide installation?

Our advertised services focus on ventilation design, commissioning and validation. Let us know what your project needs so responsibilities and the installer’s scope can be agreed clearly.

08 / LET’S TALK

Better air starts
with a conversation.

Planning a new home, reviewing an existing system or ready for commissioning? Tell us about your project.

info@
carrolltechnical.ie

Include your location, project stage and any plans or system details you have.

Email Based in Cork, Ireland