Cork, IrelandNew builds, Retrofits & existing homes
THE DETAIL THAT MAKES A DIFFERENCEComfort you can feel. Airflow you can measure.
Designed for your homeBalanced for everyday comfortMeasured on site
01 / OUR SERVICES
The right design. The right airflow.
From a considered design to measured airflow and a clear record of performance.
01
Ventilation design
All ventilation designs are completed by a qualified Mechanical Engineer. Plan the airflow before the installation. A considered layout brings the system, duct routes and room requirements together.
Insulation keeps heat in. Ventilation gives moisture and stale air a way out.
Everyday cooking, showers and drying clothes release moisture. A planned ventilation system helps remove it, while bringing outdoor air into the rooms you live in.
Manage moisture
Help control humidity and reduce condensation risk.
Refresh indoor air
Dilute indoor pollutants and remove everyday odours.
Protect comfort
Plan air movement, noise and heat loss together.
Check performance
Know what reaches each room through measured airflow.
Ventilation is only part of the picture. Persistent damp or mould can also involve leaks, cold surfaces or building defects that need investigation.
03 / KNOW YOUR OPTIONS
The right system. For the right reasons.
Airtightness, layout, access and budget all matter. Here are the benefits and the trade-offs.
HEAT RECOVERY
MVHR
Mechanical ventilation with heat recovery
Supplies filtered outdoor air to living rooms and bedrooms, and extracts from wet rooms. A heat exchanger transfers heat from outgoing air to the incoming supply.
Why choose it
Controlled supply and extract, filtration and reduced ventilation heat loss.
What to weigh up
More ductwork, higher initial cost and space for an accessible unit. Filters need regular attention; performance depends on airtightness and commissioning.
Worth considering: airtight new builds and deep retrofits with space for supply and extract ducts.
CONTINUOUS EXTRACTION
MEV
Mechanical extract ventilation
Continuously removes air from kitchens, bathrooms and utility rooms. Replacement air enters through designed background air inlets.
Why choose it
No separate supply duct network. Centralised or decentralised arrangements can suit different layouts.
What to weigh up
No heat recovery from extracted air. Air inlets and room-to-room transfer paths are essential and need careful positioning for comfort.
Worth considering: homes where full MVHR duct routes are difficult or the upgrade scope is limited.
RESPONDS TO DEMAND
DCV
Demand-controlled ventilation
Uses controls or sensors to vary ventilation with demand, such as humidity or occupancy. DCV describes a control approach, rather than one fixed system layout.
Why choose it
Can adapt airflow as the needs of the home change, limiting unnecessary ventilation when demand is lower.
What to weigh up
Sensors, air inlets and controls must work as a complete system. Heat recovery is not implied by the DCV label.
Worth considering: projects where responsive airflow suits the proposed ventilation strategy.
The easiest time to solve a duct route is while it is still a line on a drawing.
BUILDING NEW
Get it into the design early.
Coordinate the unit, ducts and ceiling terminals with the structure, insulation and other services. Allow access for filter changes and future maintenance.
Review floor plans and room uses.
Plan supply, extract and transfer paths.
Consider noise, duct resistance and external terminals.
Arrange commissioning before handover.
UPGRADING AN EXISTING HOME
Work with the home you have.
New windows and airtightness work change how a home breathes. Review ventilation alongside those upgrades, rather than waiting for condensation to appear.
Assess existing vents, fans and moisture concerns.
Use airtightness information to inform the choice.
Check attic space, access and duct routes.
Compare disruption, cost and ongoing maintenance.
A full retrofit is not the only starting point.If your existing system is noisy, poorly balanced or struggling with moisture, tell us what you are noticing. We can agree an appropriate review.Discuss your home ↗
05 / DETAILS THAT MATTER
Installed is one thing. Working is another.
A fan running does not prove that each room is receiving the airflow it needs.
Commissioning sets it up.
Measure airflow at terminals, adjust the system and balance it against the design. Record the settings and explain operation at handover.
Validation checks the result.
Review and verify the installation against the agreed requirements. Confirm the required documentation and any independence requirements before the visit.
Small mistakes can have a big effect.
Crushed ducts, excessive bends, blocked inlets, missing transfer paths and inaccessible filters can undermine a good design. Restricting terminals to hide noise can leave rooms under-ventilated.
06 / HOW CARROLL TECHNICAL WORKS
Built around your home.
Practical advice. Careful attention to detail. A straightforward conversation about what your project needs.
01
Start with the project
Tell us where you’re building, what stage you’re at and whether you need design, commissioning or validation.
02
Agree the scope
We’ll review your plans or system details, then agree the work, timing and fee with you.
03
Get clear next steps
Receive the design information, commissioning record or validation findings you need to move your project forward.
All ventilation designs are completed by a qualified Mechanical Engineer, supported by training in Nearly Zero Energy Building (NZEB) principles and ventilation.
NSAI-registered Ventilation Validator. Independent validation of ventilation system performance against the design requirements.
NZEB VentilationNZEB Fundamental Awareness
07 / YOUR QUESTIONS
Clear answers. Better decisions.
Is MVHR right for every home?
No. It depends on airtightness, layout, duct routes, budget and the work planned. An assessment can establish whether heat recovery or an extract-based strategy is appropriate.
Will ventilation solve condensation and mould?
It can help when excess indoor moisture and inadequate air exchange are contributing. It will not repair a leaking roof or eliminate a cold bridge. Persistent problems need their causes investigated.
Can I still open the windows?
Yes. Mechanical ventilation does not prevent you opening windows. A whole-home system is intended to provide planned background ventilation without relying on repeated window opening.
Does MVHR heat or cool the house?
It recovers some heat that would otherwise leave with extracted air. It is not a replacement for your heating system or air conditioning. A summer bypass does not provide active cooling.
What maintenance is involved?
Follow the manufacturer’s schedule. Depending on the system, this includes inspecting or changing filters, keeping terminals and inlets clear, and checking the unit and controls. Do not change balanced terminal settings while cleaning.
When should I arrange commissioning?
When installation is complete and the home is ready for representative measurements. Share the drawings, system details and project programme beforehand so readiness and the required records can be agreed.
How much does the service cost?
The fee depends on the property, system, location and scope. Send your plans or system details for a project-specific quotation before booking.
Do you provide installation?
Our advertised services focus on ventilation design, commissioning and validation. Let us know what your project needs so responsibilities and the installer’s scope can be agreed clearly.
08 / LET’S TALK
Better air starts with a conversation.
Planning a new home, reviewing an existing system or ready for commissioning? Tell us about your project.